    F10-C-SERIES-CHASSIS-MIB DEFINITIONS ::= BEGIN
    --  Force10 Networks, Inc.
    --  1440 McCarthy Blvd
    --  Milpitas, CA 95035-7438

    --  This module provides authoritative definitions for Force10
    --  enterprise Chassis MIB.
    --
    --  This module will be extended, as needed.
    --

    IMPORTS
        MODULE-IDENTITY, OBJECT-TYPE, 
        Gauge32, Integer32, TimeTicks
            FROM SNMPv2-SMI
        DateAndTime, DisplayString, MacAddress
            FROM SNMPv2-TC
        MODULE-COMPLIANCE, OBJECT-GROUP
            FROM SNMPv2-CONF
        f10Mgmt
            FROM FORCE10-SMI
        F10CSeriesPortType, F10CSeriesCardType, 
        F10ProcessorModuleType, F10SwDate, 
        F10MfgDate, F10ChassisMode, F10CardOperStatus,
        F10ChassisType, F10HundredthdB
            FROM FORCE10-TC;
        
    
    f10CSerChassisMib MODULE-IDENTITY
    LAST-UPDATED "200809021200Z"  -- Sep 2, 2008 12:00:00 GMT
    ORGANIZATION
      "Force10 Networks, Inc."
    CONTACT-INFO
      "Force10 Networks, Inc
       350 Holger Way
       San Jose, CA 95134
       (408) 571-3500
       support@force10networks.com
       http://www.force10networks.com"

    DESCRIPTION
       "Force10 C-Series Enterprise Chassis MIB. "

    REVISION     "200809021200Z"
    DESCRIPTION
        "Import F10CardOperStatus."

    REVISION     "200706281200Z"
    DESCRIPTION
        "Import F10ChassisType.
         Redefine XFP received power object.
        "

    REVISION     "200705221200Z"
    DESCRIPTION
        "The following changes have been made:
         - add new table: chLineCardUtilTable.
         - use gauge32 to define utilization objects.
         - add module conformance."

    REVISION     "0605010000Z"
    DESCRIPTION
          "First draft revision of Force10 c-series chassis mib."

           ::= { f10Mgmt 8 }   


    -- ### Groups ###

    f10CSerChassisObject OBJECT IDENTIFIER ::={ f10CSerChassisMib 1 }
    chObjects           OBJECT IDENTIFIER ::={ f10CSerChassisObject 1 }
    chSysObjects        OBJECT IDENTIFIER ::={ f10CSerChassisObject 2 }
    chRpmObjects        OBJECT IDENTIFIER ::={ f10CSerChassisObject 3 }
    chAlarmObjects      OBJECT IDENTIFIER ::={ f10CSerChassisObject 4 }
    chLineCardObjects   OBJECT IDENTIFIER ::={ f10CSerChassisObject 5 }
    

    -- ### Chassis Information

       chType           OBJECT-TYPE
        SYNTAX          F10ChassisType
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The type of chassis."
        ::= { chObjects 1 }

       chChassisMode  OBJECT-TYPE
        SYNTAX        F10ChassisMode
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The chassis mode of this chassis."
        ::= { chObjects 2 }

       chSwVersion  OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "Current FTOS system images software version." 
        ::= { chObjects 3 }

       chMacAddr   OBJECT-TYPE
        SYNTAX          MacAddress
         MAX-ACCESS      read-only
         STATUS          current
         DESCRIPTION
             "A 6-octet MAC Address assigned
              to this chassis.
             "
         ::= { chObjects 4 }

       chSerialNumber OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The chassis's serial number."
        ::= { chObjects 5 }

       chPartNum      OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The chassis manufacturer's part number." 
        ::= { chObjects 6 }

       chProductRev   OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The chassis manufacturer's product revision." 
        ::= { chObjects 7 }

       chVendorId     OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The chassis manufacturer vendor's id." 
        ::= { chObjects 8 }

       chDateCode     OBJECT-TYPE
        SYNTAX        F10MfgDate
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The date the chassis was manufactured.
            "
        ::= { chObjects 9 }

       chCountryCode  OBJECT-TYPE
        SYNTAX        OCTET STRING (SIZE (2))
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The chassis manufacturer's country code"
        ::= { chObjects 10 }

       chNumSlots     OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The total number of physical slots 
            in the chassis for line cards and
            route process module (rpm ) cards."
        ::= { chObjects 11 }

       chNumLinecards OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The total number of line cards 
            in the chassis.
            "
        ::= { chObjects 12 }

       chNumFanTrays  OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The total number of fan trays
            on the chassis."
        ::= { chObjects 13 }

       chNumPowerSupplies     OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The total number of power supply
            in the chassis."
        ::= { chObjects 14 }

       chNumSfmSlots  OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The total number of switch fabric
            modules (sfm) slots in the chassis."
        ::= { chObjects 15 }

    -- ### Chassis System  ###

    -- ## Card Table

    -- The chassis is a multi-slots physical box.
    -- In the chassis, there are physical slots available for
    -- plug-in cards.  There are two types of plug-in cards,
      -- rpm cards and line cards.  

       -- The card table contains the card information of  
    -- each slot in the chassis. Each slot entry containing  
    -- the management information applicable to a particular
    -- line card or route process module (rpm) card.


      chSysCardTable        OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChSysCardEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
                      "A list of cards resident in the chassis.
                      The card table contains the card information of  
                       each slot in the chassis. 
                      "
        ::= { chSysObjects 1 }

      chSysCardEntry  OBJECT-TYPE 
        SYNTAX        ChSysCardEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of cards entries containing information 
             for line card.
             
             The placement of line cards and rpm cards
             in the C300 chassis are as follows :

             ( physical slot numbers )
             1  2  3  4  5 6  7  8  9  10 
             ( Force10 card number )
             0  1  2  3  0 1  4  5  6  7
             |        |       |        |
             ----------       ----------
                 |       | |      |
             line card   | |   line card
                         | |
                         | + ----> RPM card
                         +-------> RPM card
             
             The placement of line cards and rpm cards
             in the C150 chassis are as follows :

             ( physical slot numbers )
             1  2  3 4  5  6 
             ( Force10 card number )
             0  1  0 1  2  3
             |  |       |  |
             ----       ----
              |    | |    |
         line card | | line card
                   | |
                   | + ----> RPM card
                   +-------> RPM card
             "
        INDEX    { chSysCardSlotIndex }
        ::= { chSysCardTable 1 }

      ChSysCardEntry    ::=
        SEQUENCE {
           chSysCardSlotIndex       Integer32,
           chSysCardType            F10CSeriesCardType,
           chSysCardNumber          Integer32,
           chSysCardNumPorts        Integer32,
           chSysCardTemp            Gauge32,
           chSysCardUpTime          TimeTicks,
           chSysCardAdminStatus     INTEGER,
           chSysCardOperStatus      F10CardOperStatus,
           chSysCardBootFlashA      DisplayString,
           chSysCardBootFlashB      DisplayString,
           chSysCardSerialNumber    DisplayString,
           chSysCardPartNum         DisplayString,
           chSysCardProductRev      DisplayString,
           chSysCardVendorId        DisplayString,
           chSysCardDateCode        F10MfgDate,
           chSysCardCountryCode     OCTET STRING
        }

       chSysCardSlotIndex    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                 "A unique index for each slot within 
                the chassis.
                This value is the physical slot number
                and the value is determined 
                by the chassis slot location where
                          the card is inserted.  Valid entries
                          are 1 to the value of chNumSlots."
        ::= { chSysCardEntry 1 }

       chSysCardType  OBJECT-TYPE
        SYNTAX        F10CSeriesCardType
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "Type of card in this slot.  The type
            of cards are defined in F10CSeriesCardType."
        ::= { chSysCardEntry 2 }

       chSysCardNumber    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This is the card number assigned to the line 
            cards and the RPM cards in the chassis.
            The line cards number are from 0 to 6.
            "
        ::= { chSysCardEntry 3 }

       chSysCardNumPorts    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The number of physical ports  
            in each card. The card can have  
            one or more ports depending on
            the type of cards.
            If it is a logical card,
            the value set to zero.
            "
        ::= { chSysCardEntry 4 }

       chSysCardTemp  OBJECT-TYPE
        SYNTAX        Gauge32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The temperature of the card. 
            "
        ::= { chSysCardEntry 5 }

       chSysCardUpTime    OBJECT-TYPE
        SYNTAX        TimeTicks
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The SysUpTime for this slot.
            This variable indicates the
            time since the card  
            last reset."
        ::= { chSysCardEntry 6 }

       chSysCardAdminStatus OBJECT-TYPE
        SYNTAX      INTEGER {
                        up(1),
                        down(2)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The admin status of the card.
            The valid status are as followed:
            'up'   - card present and ready.
            'down' - card is not ready."
        ::= { chSysCardEntry 7 }

       chSysCardOperStatus    OBJECT-TYPE
        SYNTAX      F10CardOperStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current operational state of the card."
        ::= { chSysCardEntry 8 }

       chSysCardBootFlashA    OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The software version of the boot flash.
             The card is booted with this boot image A. 
            "
        ::= { chSysCardEntry 9 }

       chSysCardBootFlashB    OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The software version of the boot flash.
             The card is booted with this boot image B. 
            "
        ::= { chSysCardEntry 10 }

       chSysCardSerialNumber    OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The serial number of the card in this slot."
        ::= { chSysCardEntry 11 }

       chSysCardPartNum    OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The card part number"
        ::= { chSysCardEntry 12 }

       chSysCardProductRev    OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The card manufacturer's product
            revision"
        ::= { chSysCardEntry 13 }

       chSysCardVendorId    OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The vendor id that manufactured the 
            card in this slot."
        ::= { chSysCardEntry 14 }

       chSysCardDateCode    OBJECT-TYPE
        SYNTAX        F10MfgDate
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The date the card is manufactured."
        ::= { chSysCardEntry 15 }

       chSysCardCountryCode    OBJECT-TYPE
        SYNTAX        OCTET STRING (SIZE (2))
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The card manufacturer's country
            code"
        ::= { chSysCardEntry 16 }

    -- ## Port Table 

       chSysPortTable OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChSysPortEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of ports in a slot."
        ::= { chSysObjects 2 }

      chSysPortEntry  OBJECT-TYPE 
        SYNTAX        ChSysPortEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A port entry containing objects for a
            particular slot."
        INDEX    { chSysPortSlotIndex,chSysPortIndex }
        ::= { chSysPortTable 1 }

      ChSysPortEntry    ::=
        SEQUENCE {
           chSysPortSlotIndex   Integer32,
           chSysPortIndex       Integer32,
           chSysPortType        F10CSeriesPortType,
           chSysPortAdminStatus INTEGER,
           chSysPortOperStatus  INTEGER,
           chSysPortIfIndex     Integer32,           
           chSysXfpRecvPower    F10HundredthdB
        }

       chSysPortSlotIndex    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "A unique index for each slot within 
                the chassis. This value is determined by 
                the chassis slot number where the card
                          is inserted.  Valid entries are 1
                          to the value of chNumSlots"        
        ::= { chSysPortEntry 1 }

       chSysPortIndex OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "A unique index for each slot within the card.
                     This value is determined by the variable 
            chSysSlotNumPorts. This value can also be 
            determined by the chSysCardType.
            Valid entries are 1 to the value of 
            number of ports availabled"
        ::= { chSysPortEntry 2 }

       chSysPortType  OBJECT-TYPE
        SYNTAX        F10CSeriesPortType
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The type of port in the card."
        ::= { chSysPortEntry 3 }

       chSysPortAdminStatus    OBJECT-TYPE
        SYNTAX      INTEGER {
                        up(1),
                        down(2)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The admin status of the card.
            The port admin status is Up if 
            the user has configured it to be up 
            otherwise, the admin status is Down."
        ::= { chSysPortEntry 4 }

       chSysPortOperStatus    OBJECT-TYPE
        SYNTAX      INTEGER {
                      ready(1),
                      portDown(2),
                      portProblem(3),
                      cardProblem(4),
                      cardDown(5),
                      notPresent(6)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The operational status provides further
            condition of the card.
            If the chSysPortAdminStatus is 'up', the 
            valid state is
            'ready' - the card is present and 
                    ready and the chSysPortAdminStatus
                    status is 'up'.
            'portDown'    - the port is down or not enabled.
            'portProblem' - port hardware problems.
                        'cardProblem' - not used.  Same as cardDown.
            'cardDown'    - the card is downed.
            'notPresent' - the card is not present."
        ::= { chSysPortEntry 5 }

       chSysPortIfIndex    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The index of ifIndex in the Interface Mib.
            This index can link to the ifEntry to get
            this interface/port information"
        ::= { chSysPortEntry 6 }

       chSysXfpRecvPower    OBJECT-TYPE
        SYNTAX        F10HundredthdB
        UNITS         "dB"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "
            The power signal strength (dB) received for
            interface on 10G linecard.
            "
        ::= { chSysPortEntry 7 }

    -- ## Processor Table 

    -- Each card has one or more processors.
       -- The Processor table contains information on the  
    -- processor and the memory.

       chSysProcessorTable    OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChSysProcessorEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of Processors resident in this slot."
        ::= { chSysObjects 3 }

      chSysProcessorEntry    OBJECT-TYPE 
        SYNTAX        ChSysProcessorEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of Processor entries."
        INDEX    { chSysProcessorSlotIndex, chSysProcessorIndex }
        ::= { chSysProcessorTable 1 }

      ChSysProcessorEntry    ::=
        SEQUENCE {
           chSysProcessorSlotIndex    Integer32,
           chSysProcessorIndex        Integer32,
           chSysProcessorModule       F10ProcessorModuleType,
           chSysProcessorUpTime       TimeTicks,
           chSysProcessorNvramSize    Integer32,
           chSysProcessorMemSize      Integer32
        }

       chSysProcessorSlotIndex        OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "A unique index for each slot within 
                the chassis. This value is determined by 
                the chassis slot number where the card
                          is inserted.  Valid entries are 1
                          to the value of chNumSlots"
        ::= { chSysProcessorEntry 1 }

       chSysProcessorIndex    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "A unique index for each Processor within the
                 card.    This value is determined by the variable 
                chSysSlotNumProcessors. the valid entries 
                are 1 to the value of number of processors"
        ::= { chSysProcessorEntry 2 }

       chSysProcessorModule    OBJECT-TYPE
        SYNTAX        F10ProcessorModuleType
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The type of module running on the Processor."
        ::= { chSysProcessorEntry 3 }

       chSysProcessorUpTime    OBJECT-TYPE
        SYNTAX        TimeTicks
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The SysUpTime for this Processor."
        ::= { chSysProcessorEntry 4 }

       chSysProcessorNvramSize    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "Total Non-volatile RAM in Kbytes."
        ::= { chSysProcessorEntry 5 }

       chSysProcessorMemSize    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The size of the RAM in Mb."
        ::= { chSysProcessorEntry 6 }

    -- ## Software Module Table 

       chSysSwModuleTable    OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChSysSwModuleEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of software version information in 
            a processor."
        ::= { chSysObjects 4 }

      chSysSwModuleEntry    OBJECT-TYPE 
        SYNTAX        ChSysSwModuleEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A software module entry containing version 
            number information for a particular processor."
        INDEX    { chSysSwSlotIndex,chSysSwProcessorIndex }
        ::= { chSysSwModuleTable 1 }

      ChSysSwModuleEntry    ::=
        SEQUENCE {
           chSysSwSlotIndex             Integer32,
           chSysSwProcessorIndex        Integer32,
           chSysSwRuntimeImgVersion     DisplayString,
           chSysSwRuntimeImgDate        F10SwDate,
           chSysSwCurrentBootImgVersion DisplayString,
           chSysSwCurrentBootImgDate    DateAndTime,
           chSysSwCurrentBootImgStatus  INTEGER,
           chSysSwBackupBootImgVersion  DisplayString,
           chSysSwBackupBootImgDate     DateAndTime,
           chSysSwBackupBootImgStatus   INTEGER,
           chSysSwNextRebootImage       INTEGER,
           chSysSwCurrentBootImage      INTEGER
        }

       chSysSwSlotIndex    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "A unique index for each slot within 
                the chassis. This value is determined by 
                the chassis slot number where the card
                          is inserted.  Valid entries are 1
                          to the value of chNumSlots"
        ::= { chSysSwModuleEntry 1 }

       chSysSwProcessorIndex        OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "A unique index for each CPU within the card.
                   This value is determined by the variable 
                chSysSlotNumCPUs. This value can also be 
                determined by the chSysSlotType.
                Valid entries are 1 to the value of 
                number of cpu"
        ::= { chSysSwModuleEntry 2 }

       chSysSwRuntimeImgVersion    OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This variable indicates the software 
            module version that is currently
            running on the processor.  
            The software release version is in 
            the format as follow:
            <major version>.<minor version>.<minor 
            version>......
            '1.1' indicate major version of 1 and
            minor release of 1."    
        ::= { chSysSwModuleEntry 3 }

       chSysSwRuntimeImgDate    OBJECT-TYPE
        SYNTAX        F10SwDate
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The release date of this software
            module."
        ::= { chSysSwModuleEntry 4 }

       chSysSwCurrentBootImgVersion    OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The software release version is in 
            the format as follow:
            <major version>.<minor version>.<minor 
            version>......
            '1.1' indicate major version of 1 and
            minor release of 1."    
        ::= { chSysSwModuleEntry 5 }

       chSysSwCurrentBootImgDate    OBJECT-TYPE
        SYNTAX        DateAndTime
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The release date of this software module
            If the CPU is reset, the software module
            running date (chSysSwModuleRunningDate) 
            will change to this current date."
        ::= { chSysSwModuleEntry 6 }

       chSysSwCurrentBootImgStatus    OBJECT-TYPE
        SYNTAX        INTEGER {
                        ok(1),
                        failed(2)
                      }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "Fill this in later"
        ::= { chSysSwModuleEntry 7 }

       chSysSwBackupBootImgVersion OBJECT-TYPE
        SYNTAX          DisplayString
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The software release version is in
                the format as follow:
                <major version>.<minor version>.<minor
                version>......
                '1.1' indicate major version of 1 and
                minor release of 1."
        ::= { chSysSwModuleEntry 8 }

       chSysSwBackupBootImgDate    OBJECT-TYPE
       SYNTAX          DateAndTime
       MAX-ACCESS      read-only
       STATUS          current
       DESCRIPTION
               "The backup boot image released date."
       ::= { chSysSwModuleEntry 9 }

       chSysSwBackupBootImgStatus  OBJECT-TYPE
       SYNTAX          INTEGER {
                           ok(1),
                           failed(2)
                       }
       MAX-ACCESS      read-only
       STATUS          current
       DESCRIPTION
            "The status of the backup boot image."
       ::= { chSysSwModuleEntry 10 }

       chSysSwNextRebootImage  OBJECT-TYPE
       SYNTAX          INTEGER {
                           bootImage-A(1),
                           bootImage-B(2)
                       }
       MAX-ACCESS      read-only
       STATUS          current
       DESCRIPTION
        "The boot flash image selection. When the
         chassis is rebooted, this is the boot 
         image to use."
       ::= { chSysSwModuleEntry 11 }

       chSysSwCurrentBootImage  OBJECT-TYPE
       SYNTAX          INTEGER {
                           bootImage-A(1),
                           bootImage-B(2)
                       }
       MAX-ACCESS      read-only
       STATUS          current
       DESCRIPTION
        "The current boot image. This is the boot image described by the 
        chSysSwCurrentBootImgVersion, chSysSwCurrentBootImgDate, and
        chSysSwCurrentBootImgStatus objects.   
        "
       ::= { chSysSwModuleEntry 12 }


    -- ### Power Supply Table 

       chSysPowerSupplyTable    OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChSysPowerSupplyEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of power supply resident 
            in this chassis."
        ::= { chSysObjects 5 }

      chSysPowerSupplyEntry    OBJECT-TYPE 
        SYNTAX        ChSysPowerSupplyEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A power supply entry containing objects for a
            particular power supply."
        INDEX    { chSysPowerSupplyIndex }
        ::= { chSysPowerSupplyTable 1 }

      ChSysPowerSupplyEntry    ::=
        SEQUENCE {
           chSysPowerSupplyIndex        Integer32,
           chSysPowerSupplyOperStatus   INTEGER,        
           chSysPowerSupplyType         INTEGER        
        }

       chSysPowerSupplyIndex    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The unique index of the power supply."
        ::= { chSysPowerSupplyEntry 1 }

       chSysPowerSupplyOperStatus    OBJECT-TYPE
        SYNTAX      INTEGER {
                        up(1),
                        down(2)
                    }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The status of the power supply."
        ::= { chSysPowerSupplyEntry 2 }

       chSysPowerSupplyType    OBJECT-TYPE
        SYNTAX      INTEGER {
                        ac(1),
                        dc(2)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The type of the power supply."
        ::= { chSysPowerSupplyEntry 3 }

    -- ## Fan Tray Table 

       chSysFanTrayTable    OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChSysFanTrayEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of fan tray resident in this chassis."
        ::= { chSysObjects 6 }

      chSysFanTrayEntry    OBJECT-TYPE 
        SYNTAX        ChSysFanTrayEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A fan entry containing objects for a
            particular fan tray."
        INDEX    { chSysFanTrayIndex }
        ::= { chSysFanTrayTable 1 }

      ChSysFanTrayEntry    ::=
        SEQUENCE {
           chSysFanTrayIndex        Integer32,
           chSysFanTrayOperStatus   INTEGER        
        }

       chSysFanTrayIndex    OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The unique index of the fan tray."
        ::= { chSysFanTrayEntry 1 }

       chSysFanTrayOperStatus    OBJECT-TYPE
        SYNTAX      INTEGER {
                        up(1),
                        down(2)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The status of the fan tray."
        ::= { chSysFanTrayEntry 2 }

    -- ## SFM Table 

       chSysSfmTable  OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChSysSfmEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of Swicth Fabric Module in a slot."
        ::= { chSysObjects 7 }

      chSysSfmEntry   OBJECT-TYPE 
        SYNTAX        ChSysSfmEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A SFM entry containing objects for a
            particular slot."
        INDEX    { chSysSfmIndex }
        ::= { chSysSfmTable 1 }

      ChSysSfmEntry    ::=
        SEQUENCE {
           chSysSfmIndex            Integer32,
           chSysSfmAdminStatus      INTEGER,
           chSysSfmOperStatus       INTEGER,
           chSysSfmErrorStatus      INTEGER
        }

       chSysSfmIndex  OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "A unique index for each SFM within 
                the chassis. The number of SFM slots 
                can be determined with chNumSfmSlots." 
        ::= { chSysSfmEntry 1 }

       chSysSfmAdminStatus    OBJECT-TYPE
        SYNTAX      INTEGER {            
                        up(1),
                        down(2)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The admin status of 
                each SFM."
        ::= { chSysSfmEntry 2 }


       chSysSfmOperStatus    OBJECT-TYPE
        SYNTAX      INTEGER {                
                        active(1),
                        absent(2),
                        standby(3)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The Operational status provides further
            condition of Switch Fabric Module card.
            If the chSysSfmAdminStatus is 'up', the 
            valid state is
            'active' - the card is present and 
                    ready and the chSysSfmAdminStatus
                    status is 'up'.
            If the chSysCardOperStatus is 'down', the 
            service states can be as followed:
            'absent'      - the card is not present.
            'standby'     - the card is in standby
                        mode."
        ::= { chSysSfmEntry 3 }

       chSysSfmErrorStatus    OBJECT-TYPE
        SYNTAX      INTEGER {                
                        ok(1),
                        error(2),
                        not-available(3)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The Operational status provides further
            condition of Switch Fabric Module card.
            If the chSysSfmAdminStatus is 'up', the 
            valid state is
            'ok' - the card is present and 
                    ready and the chSysSfmAdminStatus
                    status is 'up'.
            If the chSysSfmAdminStatus is 'down', the 
            error status can be as followed:
            'not-available'  - status not available.
            'error'       - the card is in error state."
        ::= { chSysSfmEntry 4 }


    -- ## Primary Routing Process Module

       chRpmNumRpms   OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The number of RPM installed
            in the chassis.  There is always one
            primary RPM, but a secondary RPM can
            also be installed as backup."
        ::= { chRpmObjects 1 }

       chRpmSlotNumber  OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The primary routing process module
            slot number.  If the primary RPM is
            switched to secondary RPM, the slot
            number will be updated here." 
        ::= { chRpmObjects 2 }

       chRpmUptime    OBJECT-TYPE
        SYNTAX        TimeTicks
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "SysUpTime of the last time the RPM
            is reset.  Used the SysUpTime of the 
            control processor as this variable." 
        ::= { chRpmObjects 3 }

       chRpmLastSwitchDate    OBJECT-TYPE
        SYNTAX        DateAndTime
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The date and time when the Routing
            Process Module is switched." 
        ::= { chRpmObjects 4 }

       chRpmMajorAlarmStatus    OBJECT-TYPE
        SYNTAX        INTEGER {
                        off(1),
                        on(2)
                      }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The Major Alarm LED on the Primary RPM card."
        ::= { chRpmObjects 5 }

       chRpmMinorAlarmStatus    OBJECT-TYPE
        SYNTAX      INTEGER {
                        off(1),
                        on(2)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The Minor Alarm LED on the Primary RPM card."
        ::= { chRpmObjects 6 }

    -- ## Primary Routing Process Module CPU and Memory Utilization

       chRpmUtilTable OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChRpmUtilEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A table listing the cpu and memory utilization
             in master RPM."
        ::= { chRpmObjects 7  }

      chRpmUtilEntry  OBJECT-TYPE 
        SYNTAX        ChRpmUtilEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A row in each processor cpu and mmory utilization"
        INDEX    { chRpmCpuIndex }
        ::= { chRpmUtilTable 1 }

      ChRpmUtilEntry    ::=
        SEQUENCE {
           chRpmCpuIndex        Integer32,
           chRpmCpuType         F10ProcessorModuleType,
           chRpmCpuUtil5Sec     Gauge32,
           chRpmCpuUtil1Min     Gauge32,
           chRpmCpuUtil5Min     Gauge32,
           chRpmMemUsageUtil    Gauge32
        }

       chRpmCpuIndex  OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "A unique index for each Processor within the
                 RPM.    This value is determined by the variable 
                chSysSlotNumProcessors. the valid entries 
                are 1 to the value of number of processors"
        ::= { chRpmUtilEntry 1 }

       chRpmCpuType   OBJECT-TYPE
        SYNTAX        F10ProcessorModuleType
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The type of module running on the Processor."
        ::= { chRpmUtilEntry 2 }

       chRpmCpuUtil5Sec OBJECT-TYPE
        SYNTAX          Gauge32(0..100)
        UNITS           "percent"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "CPU utilization in percentage for last 5 seconds."
        ::= { chRpmUtilEntry 3 }

       chRpmCpuUtil1Min     OBJECT-TYPE
        SYNTAX              Gauge32(0..100)
        UNITS               "percent"
        MAX-ACCESS          read-only
        STATUS              current
        DESCRIPTION
            "CPU utilization in percentage for last 1 minute."
        ::= { chRpmUtilEntry 4 }

       chRpmCpuUtil5Min     OBJECT-TYPE
        SYNTAX              Gauge32(0..100)
        UNITS               "percent"
        MAX-ACCESS          read-only
        STATUS              current
        DESCRIPTION
            "CPU utilization in percentage for last 5 minutes."
        ::= { chRpmUtilEntry 5 }

       chRpmMemUsageUtil    OBJECT-TYPE
        SYNTAX              Gauge32(0..100)
        UNITS               "percent"
        MAX-ACCESS          read-only
        STATUS              current
        DESCRIPTION
            "Total RPM's memory usage in percentage."
        ::= { chRpmUtilEntry 6 }

    -- ## Line card CPU and Memory Utilization

       chLineCardUtilTable OBJECT-TYPE
        SYNTAX        SEQUENCE OF ChLineCardUtilEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A table listing the cpu and memory utilization
             in line cards."
        ::= { chLineCardObjects 1  }

      chLineCardUtilEntry  OBJECT-TYPE
        SYNTAX        ChLineCardUtilEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A row in each line card cpu and memory utilization"
        INDEX    { chSysCardNumber }
        ::= { chLineCardUtilTable 1 }

      ChLineCardUtilEntry    ::=
        SEQUENCE {
           chLineCardCpuUtil5Sec     Gauge32,
           chLineCardCpuUtil1Min     Gauge32,
           chLineCardCpuUtil5Min     Gauge32,
           chLineCardMemUsageUtil    Gauge32
        }

      chLineCardCpuUtil5Sec OBJECT-TYPE
        SYNTAX        Gauge32(0..100)
        UNITS         "percent"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "CPU utilization in percentage for last 5 seconds."
        ::= { chLineCardUtilEntry 1 }

       chLineCardCpuUtil1Min OBJECT-TYPE
        SYNTAX        Gauge32(0..100)
        UNITS         "percent"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "CPU utilization in percentage for last 1 minute."
        ::= { chLineCardUtilEntry 2 }

       chLineCardCpuUtil5Min OBJECT-TYPE
        SYNTAX        Gauge32(0..100)
        UNITS         "percent"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "CPU utilization in percentage for last 5 minutes."
        ::= { chLineCardUtilEntry 3 }

       chLineCardMemUsageUtil OBJECT-TYPE
        SYNTAX        Gauge32(0..100)
        UNITS         "percent"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "Memory usage in percentage."
        ::= { chLineCardUtilEntry 4 }

    
    -- ### conformance information ###
    f10CSerChassisMibConformance    OBJECT IDENTIFIER ::= { f10CSerChassisMib 2 }
    f10CSerChassisMibCompliances    OBJECT IDENTIFIER ::= { f10CSerChassisMibConformance 1 }
    f10CSerChassisMibGroups         OBJECT IDENTIFIER ::= { f10CSerChassisMibConformance 2 }

    -- ## compliance statements
    f10CSerChassisMibCompliance MODULE-COMPLIANCE
        STATUS                  current
        DESCRIPTION
            "The compliance statement for Force10
            product which implement the C-Series
            Chassis MIB."
        MODULE    -- this module
        MANDATORY-GROUPS {
            f10CSerComponentGroup,
            f10CSerSystemGroup,
            f10CSerRpmGroup,
            f10CSerLineCardGroup
        }
        ::= { f10CSerChassisMibCompliances 1 }

    -- ## units of conformance

    f10CSerComponentGroup    OBJECT-GROUP
        OBJECTS {
        chType,
        chChassisMode,
        chSwVersion,
        chMacAddr,
        chSerialNumber,
        chPartNum,
        chProductRev,
        chVendorId,
        chDateCode,
        chCountryCode,
        chNumSlots,
        chNumLinecards,
        chNumFanTrays,
        chNumPowerSupplies,
        chNumSfmSlots
        }
        STATUS    current
        DESCRIPTION
            "A collection of objects providing the
            overall chassis information."
        ::= { f10CSerChassisMibGroups 1 }

    f10CSerSystemGroup    OBJECT-GROUP
        OBJECTS {
        chSysCardType,
        chSysCardNumber,
        chSysCardNumPorts,
        chSysCardTemp,
        chSysCardUpTime,
        chSysCardAdminStatus,
        chSysCardOperStatus,
        chSysCardBootFlashA,
        chSysCardBootFlashB,
        chSysCardSerialNumber,
        chSysCardPartNum,
        chSysCardProductRev,
        chSysCardVendorId,
        chSysCardDateCode,
        chSysCardCountryCode,
        chSysPortType,
        chSysPortAdminStatus,
        chSysPortOperStatus,
        chSysPortIfIndex,
        chSysXfpRecvPower,
        chSysProcessorModule,
        chSysProcessorUpTime,
        chSysProcessorNvramSize,
        chSysProcessorMemSize,
        chSysSwRuntimeImgVersion,
        chSysSwRuntimeImgDate,
        chSysSwCurrentBootImgVersion,
        chSysSwCurrentBootImgDate,
        chSysSwCurrentBootImgStatus,
        chSysSwBackupBootImgVersion,
        chSysSwBackupBootImgDate,
        chSysSwBackupBootImgStatus,
        chSysSwNextRebootImage,
        chSysSwCurrentBootImage,
        chSysPowerSupplyOperStatus,
        chSysPowerSupplyType,
        chSysFanTrayOperStatus,
        chSysSfmAdminStatus,
        chSysSfmOperStatus,
        chSysSfmErrorStatus
        }
        STATUS    current
        DESCRIPTION
            "A collection of objects providing the
            chassis system hardware information."
        ::= { f10CSerChassisMibGroups 2 }

    f10CSerRpmGroup    OBJECT-GROUP
        OBJECTS {
        chRpmNumRpms,
        chRpmSlotNumber,
        chRpmUptime,
        chRpmLastSwitchDate,
        chRpmMajorAlarmStatus,
        chRpmMinorAlarmStatus,
        chRpmCpuType,
        chRpmCpuUtil5Sec,
        chRpmCpuUtil1Min,
        chRpmCpuUtil5Min,
        chRpmMemUsageUtil
        }
        STATUS    current
        DESCRIPTION
            "A collection of objects providing the
            Route Process Module (RPM) information."
        ::= { f10CSerChassisMibGroups 3 }

    f10CSerLineCardGroup    OBJECT-GROUP
        OBJECTS {
        chLineCardCpuUtil5Sec,
        chLineCardCpuUtil1Min,
        chLineCardCpuUtil5Min,
        chLineCardMemUsageUtil
        }
        STATUS    current
        DESCRIPTION
            "A collection of objects providing
            CPU and Memory Utilization in the Line cards."
        ::= { f10CSerChassisMibGroups 4 }