-- Quido.txt: MIB corespording to QUIDOSNMP-10.C
--
--
-- September 2003 Steiger Miroslav
-- Copyringht (c) 2003 by PaPouch elektronika

--*********************************

QUIDOS-MIB DEFINITIONS ::= BEGIN

IMPORTS  
--      MODULE-IDENTITY,
--      OBJECT-TYPE,
--      NOTIFICATION-TYPE,
                enterprises,
                IpAddress,
                Counter,
                TimeTicks
        FROM RFC1155-SMI
    OBJECT-TYPE
                FROM RFC-1212    
        DisplayString
                FROM RFC1213-MIB
        TRAP-TYPE
                FROM RFC-1215
    ;
    
papouchProjekt     OBJECT IDENTIFIER ::= { enterprises 18248 }
--OID 1.3.6.1.4.1.18248.16
quidos                 OBJECT IDENTIFIER ::= { papouchProjekt 16 }

quido-var          OBJECT IDENTIFIER ::= { quidos 1 }
table-in           OBJECT IDENTIFIER ::= { quidos 2 }   
table-out          OBJECT IDENTIFIER ::= { quidos 3 } 
table-term         OBJECT IDENTIFIER ::= { quidos 4 }

--
-- Type Definitions
--

PositiveInteger ::= INTEGER (0..65535)

OnOff ::= INTEGER {
                off (0),
                on (1)
        }

StatCit ::= INTEGER {
    none (0),
    falling(1),
    rising(2),
    both(3)    
}
--OID 1.3.6.1.4.1.18248.16.1.1.0
temperatureReading OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          current
        DESCRIPTION     "temperature value / 10"
::= { quido-var 1 }
--OID 1.3.6.1.4.1.18248.16.1.2.0
temperature-S-Reading OBJECT-TYPE
    SYNTAX DisplayString
        ACCESS read-only
        STATUS current
        DESCRIPTION     "temperature value as string"
::= { quido-var 2 }
--OID 1.3.6.1.4.1.18248.16.1.3.0
user-name OBJECT-TYPE
    SYNTAX DisplayString
        ACCESS read-write
        STATUS current
        DESCRIPTION     "user name is user string"
::= { quido-var 3 }
--OID 1.3.6.1.4.1.18248.16.1.4.0
device-msg OBJECT-TYPE
    SYNTAX DisplayString
        ACCESS read-only
        STATUS current
        DESCRIPTION     "msg"
::= { quido-var 4 }
          
temp-msg TRAP-TYPE
        ENTERPRISE quido-var
        VARIABLES {user-name,device-msg}
                DESCRIPTION "tento trap je odesilan pri zmenach vstupu "
            ::= 1
   
 ---
 --- TABULKA PRO PARAMETRY VSTUPU
 ---
 inTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF InEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION     ""
 ::= { table-in 1 }

 inEntry OBJECT-TYPE
        SYNTAX  InEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION     ""
        INDEX   { index }
 ::= { inTable 1 }

 InEntry ::=
    SEQUENCE {
        in
            OnOff,
        in-name
            DisplayString, 
                citrwS
                    StatCit,
                citrw
                    INTEGER
    } 
--
-- parametry pro cteni vstupu
--
--OID 1.3.6.1.4.1.18248.16.2.1.1.1.1- len-in                 
in  OBJECT-TYPE
        SYNTAX          OnOff
        ACCESS          read-only
        STATUS          current
        DESCRIPTION     "0 = OFF, 1 = ON"
::= { inEntry 1 }   
--
-- parametry pro cteni nastaveni jmena vstupu
--  
--OID 1.3.6.1.4.1.18248.16.2.1.1.2.1- len-in 
in-name OBJECT-TYPE
    SYNTAX DisplayString
        ACCESS read-write
        STATUS current
        DESCRIPTION     "user name is user string"
::= { inEntry 2 }
--
-- parametry pro cteni nastaveni citacu
--  
--OID 1.3.6.1.4.1.18248.16.2.1.1.3.1- len-in; max 60 
citrwS OBJECT-TYPE
        SYNTAX          StatCit
        ACCESS          read-write
        STATUS          current
        DESCRIPTION     "0 = none, 1 = rising, 2 = falling, 3 = both"
::= { inEntry 3 }
--
-- parametry pro cteni hodnoty citace popripade odecet od citace
--                                
--OID 1.3.6.1.4.1.18248.16.2.1.1.4.1- len-in; max 60
citrw OBJECT-TYPE
        SYNTAX          INTEGER (0..65535)
        ACCESS          read-write
        STATUS          current
        DESCRIPTION     "cteni citacu nebo odecet od citace"
::= { inEntry 4 } 
---
--- TABULKA PRO PARAMETRY VYSTUPU
---               

 outTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF OutEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION     ""
 ::= { table-out 1 }

 outEntry OBJECT-TYPE
        SYNTAX  OutEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION     ""
        INDEX   { index }
 ::= { outTable 1 }

OutEntry ::=
    SEQUENCE {
        out
            OnOff,
        out-name
            DisplayString, 
                outTwr
                    INTEGER
    } 
 --
-- parametry pro nastaveni cteni vystupu
--  
--OID 1.3.6.1.4.1.18248.16.3.1.1.1.1- len-out
out OBJECT-TYPE
        SYNTAX          OnOff
        ACCESS          read-write
        STATUS          current
        DESCRIPTION     "0 = OFF, 1 = ON"
::= { outEntry 1 }  
--
-- parametry pro cteni nastaveni jmena vystupu
--
--OID 1.3.6.1.4.1.18248.16.3.1.1.2.1- len-out   
out-name OBJECT-TYPE
    SYNTAX DisplayString
        ACCESS read-write
        STATUS current
        DESCRIPTION     "user name is user string"
::= { outEntry 2 }
--
-- parametry pro nastaveni a cteni casu vystupu
--                                
--OID 1.3.6.1.4.1.18248.16.3.1.1.3.1- len-out
outTwr OBJECT-TYPE
        SYNTAX          INTEGER 
        ACCESS          read-write
        STATUS          current
        DESCRIPTION     "0 - 255"
::= { outEntry 3 }
---
--- TABULKA PRO PARAMETRY HLIDANI TEPLOTY
---
 termTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF TermEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION     ""
 ::= { table-term 1 }

 termEntry OBJECT-TYPE
        SYNTAX  TermEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION     ""
        INDEX   { index }
 ::= { termTable 1 }

TermEntry ::=
    SEQUENCE {
        modeTerm
            INTEGER,
        mezHi
            INTEGER, 
        mezLo
            INTEGER, 
        time
            INTEGER, 
        err
            INTEGER 
    } 
--OID 1.3.6.1.4.1.18248.16.4.1.1.1.1- len-out    
modeTerm OBJECT-TYPE
        SYNTAX          INTEGER(0..6)
        ACCESS          read-write
        STATUS          current
        DESCRIPTION     "0 = vypnut,
                     1 = prekroci li teplota hodnotu mezHi1 sepne rele1, klesne li pod hodnotu mezLo1 rozepne rele1
                     2 = prekroci li teplota hodnotu mezHi1 rozepne rele1, klesne li pod hodnotu mezLo1 sepne rele1                  
                     3 = prekroci li teplota hodnotu mezHi1 sepne rele1 na dobu v parametru time1.
                         pri opetovnem prekroceni se udalost vyvola klesla li teplota od
                         predchozi udalosti na hodnotu v mezLo1
                     4 = prekroci li teplota hodnotu mezHi1 rozepne rele1 na dobu v parametru time1.
                         pri opetovnem prekroceni se udalost vyvola klesla li teplota od
                         predchozi udalosti na hodnotu v mezLo1   
                     5 = klesne li teplota pod hodnotu mezLo1 sepne rele1 na dobu v parametru time1.
                         pri opetovnem poklesu teploty se udalost vyvola stoupla li teplota od 
                         predchozi udalosti na hodnotu v mezHi1   
                     6 = klesne li teplota pod hodnotu mezLo1 sepne rele1 na dobu v parametru time1.
                         pri opetovnem poklesu teploty se udalost vyvola stoupla li teplota od 
                         predchozi udalosti na hodnotu v mezHi1                                                  
                    "
                     
::= { termEntry 1 }
--OID 1.3.6.1.4.1.18248.16.4.1.1.2.1- len-out
 mezHi OBJECT-TYPE
        SYNTAX          INTEGER(-550..1250)
        ACCESS          read-write
        STATUS          current
        DESCRIPTION     "nastavuji horni mez teploty v intervalu -550 .. +1250
                     zpusob zapisu: pozadovana hodnota * 10
                     nesmi byt mensi nez mezLo1    
                    "
::= { termEntry 2 }
--OID 1.3.6.1.4.1.18248.16.4.1.1.3.1- len-out
mezLo OBJECT-TYPE
        SYNTAX          INTEGER(-550..1250)
        ACCESS          read-write
        STATUS          current
        DESCRIPTION     "nastavuji dolni mez teploty v intervalu -550 .. +1250
                     zpusob zapisu: pozadovana hodnota * 10
                     nesmi byt vetsi nez mezHi1    
                    "
::= { termEntry 3 }
--OID 1.3.6.1.4.1.18248.16.4.1.1.4.1- len-out
time OBJECT-TYPE
        SYNTAX          INTEGER(0..255)
        ACCESS          read-write
        STATUS          current
        DESCRIPTION     "zde je uvedena doba po kterou bude rele1 po vyvolani udalosti sepnuto nebo rozepnuto
                     tato doba je ve vterinach
                    "
::= { termEntry 4 }
--OID 1.3.6.1.4.1.18248.16.4.1.1.5.1- len-out
err OBJECT-TYPE
         SYNTAX         INTEGER(0..2)
         ACCESS         read-write
         STATUS         current
         DESCRIPTION    "parametr urcujici v jakem stavu ma byt rele2 dojde li k chybe teplotniho cidla
                         0 = nechat ve stavu ve kterem se rele nachazi
                         1 = rozepnout rele2
                         2 = sepnout rele2
                        "
::= { termEntry 5 }    
    
END