-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-TEMIB-ENTITY-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------

PRVT-TEMIB-ENTITY-MIB DEFINITIONS ::= BEGIN

IMPORTS
    mpls
        FROM PRVT-SWITCH-MIB
    MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
        FROM SNMPv2-SMI
    RowStatus, TEXTUAL-CONVENTION, TruthValue
        FROM SNMPv2-TC;

prvtTeMibEntityMIB MODULE-IDENTITY
    LAST-UPDATED "200712060000Z"
    ORGANIZATION 
        "BATM Advanced Communication"
    CONTACT-INFO 
        "BATM/Telco Systems Support team
         Email:
         For North America: techsupport@telco.com
         For North Europe: support@batm.de, info@batm.de
         For the rest of the world: techsupport@telco.com"
    DESCRIPTION 
        "The MIB module for management of TE-MIB entities."
    REVISION    "200712060000Z"
    DESCRIPTION 
        "Initial."
    ::= { mpls 8 }


PrvtTeMibAdminStatus ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION 
        "The desired administrative state of a TE-MIB entity."
    SYNTAX      INTEGER { up(1), down(2) }

PrvtTeMibOperStatus ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION 
        "The current operational state of a TE-MIB entity."
    SYNTAX      INTEGER { up(1), down(2), goingUp(3), goingDown(4), 
                    actFailed(5) }

PrvtTeMibEntityIndex ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS      current
    DESCRIPTION 
        "The index value identifying a TE-MIB entity."
    SYNTAX      Unsigned32

PrvtTeMibPartnerStatus ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION 
        "The state of a TE-MIB entity partner."
    SYNTAX      INTEGER { initial(0), activating(1), active(2), 
                    deactivating(3), failedOver(4), failed(5), 
                    unavailable(6) }

prvtTeMibEntityMIBObjects OBJECT IDENTIFIER
    ::= { prvtTeMibEntityMIB 1 }

prvtMplsTeMibEntityTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PrvtMplsTeMibEntityEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "The table of TE-MIB entities."
    ::= { prvtTeMibEntityMIBObjects 1 }

prvtMplsTeMibEntityEntry OBJECT-TYPE
    SYNTAX      PrvtMplsTeMibEntityEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Each entry represents a TE-MIB entity."
    INDEX       { prvtMplsTeMibEntityIndex }
    ::= { prvtMplsTeMibEntityTable 1 }

PrvtMplsTeMibEntityEntry ::= SEQUENCE {
    prvtMplsTeMibEntityIndex        PrvtTeMibEntityIndex,
    prvtMplsTeMibEntityRowStatus    RowStatus,
    prvtMplsTeMibDynFacilityBypass  TruthValue
}

prvtMplsTeMibEntityIndex OBJECT-TYPE
    SYNTAX      PrvtTeMibEntityIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "The index of this TE-MIB entity table entry. This is the
         HAF entity index passed on the entity create parameters."
    ::= { prvtMplsTeMibEntityEntry 1 }

prvtMplsTeMibEntityRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "The row status for the TE-MIB entity table entry, used to create
         and destroy TE-MIB entities.
         When prvtMplsTeMibEntityRowStatus is 'active' and
         prvtMplsTeMibEntityAdminStatus is 'up' the TE-MIB entity is active
         and only these two fields can be modified."
    ::= { prvtMplsTeMibEntityEntry 2 }

prvtMplsTeMibDynFacilityBypass OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION 
        "This object gives the user ability to globally enable/disable 
         automatically creation of bypass tunnels for all LSPs. Bypass 
         tunnels will be created on FRR tunnel request automatically.
         The default value is true. The creation of Dynamic bypass tunnels 
         is enabled"
    ::= { prvtMplsTeMibEntityEntry 3 }

mplsTunnelHoldTimer OBJECT-TYPE
    SYNTAX      Unsigned32 (0..120)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "Defines a period in seconds needed to wait before rebuilding backup 
         or primary tunnels if a frr condition occurs
         Currently no more than 10 seconds are allowed"
    ::= { prvtTeMibEntityMIBObjects 2 }

prvtMplsTeMibEntityScalarTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PrvtMplsTeMibEntityScalarEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "The mplsTeMibEntityScalarTable contains all MPLS Tunnel
         scalars."
    ::= { prvtTeMibEntityMIBObjects 3 }

prvtMplsTeMibEntityScalarEntry OBJECT-TYPE
    SYNTAX      PrvtMplsTeMibEntityScalarEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "The mplsTeMibEntityScalarTable contains all MPLS Tunnel
         scalars."
    INDEX       { prvtMplsTeMibEntityIndex }
    ::= { prvtMplsTeMibEntityScalarTable 1 }

PrvtMplsTeMibEntityScalarEntry ::= SEQUENCE {
    mplsTunnelConfigured    Unsigned32,
    mplsTunnelActive        Unsigned32
}

mplsTunnelConfigured OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The number of tunnels configured on this device. A
         tunnel is considered configured if the
         mplsTunnelRowStatus is active(1)."
    ::= { prvtMplsTeMibEntityScalarEntry 1 }

mplsTunnelActive OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The number of tunnels active on this device. A
         tunnel is considered active if the
         mplsTunnelOperStatus is up(1)."
    ::= { prvtMplsTeMibEntityScalarEntry 2 }

END -- end of module PRVT-TEMIB-ENTITY-MIB.