AC-ANALOG-MIB DEFINITIONS ::= BEGIN


    IMPORTS
       

        OBJECT-TYPE, 
        MODULE-IDENTITY                             FROM SNMPv2-SMI
        TAddress, 
        DisplayString, 
        DateAndTime, TEXTUAL-CONVENTION             FROM SNMPv2-TC
        IpAddress                                   FROM RFC1155-SMI
        Unsigned32,
		Integer32,
        enterprises                                 FROM SNMPv2-SMI
		SnmpAdminString								FROM SNMP-FRAMEWORK-MIB
		audioCodes,       
		acRegistrations,
		acGeneric, 
		acProducts,acBoardMibs						FROM AUDIOCODES-TYPES-MIB;

       
acAnalog  MODULE-IDENTITY       
    LAST-UPDATED "201207260446Z"          --Thursday, July 26 2012
    ORGANIZATION "AudioCodes Ltd"
    CONTACT-INFO
    "Postal: Support
	     AudioCodes LTD
             1 Hayarden Street
             Airport City 
	     Lod, ISRAEL 70151
     Tel:    972-3-9764000
     Fax:    972-3-9764040
     Email:  support@audiocodes.com
     Web:    www.audiocodes.com"
		

    DESCRIPTION       
    ""




    ::= {acBoardMibs 8}  








     acAnalogConfiguration OBJECT IDENTIFIER ::= {acAnalog 1}


     acAnalogConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 1}


     acAnalogMisc OBJECT IDENTIFIER ::= {acAnalogConfig 1}


     acAnalogMiscCurrentDisconnectDuration OBJECT-TYPE
       SYNTAX Unsigned32 (200..1500)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Defines the current-disconnect duration (in msec). This value
is used in generation and detection.
Access: Offline.
AC INI-Param: CurrentDisconnectDuration"
       ::= {acAnalogMisc 1}



     acAnalogMiscFlashHookPeriod OBJECT-TYPE
       SYNTAX Unsigned32 (25..3000)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Defines the flashhook period (in msec) for both analog and IP
sides.

For the analog side it defines:

- The maximal hook-flash detection period (for FXS gateways).
 A longer signal is considered offhook / onhook event. 

- The hook-flash generation period (for FXO gateways).

For the IP side it defines the flash-hook period that is reported
to IP.

The valid range is 25 to 1500. The default value is 700 msec.
Note: For FXO gateways, a constant of 90 msec must be added
to the required hook-flash period. For example, to generate
a 450 msec hook-flash, set FlashHookPeriod to 540.
.
Access: Instant.
AC INI-Param: FLASHHOOKPERIOD"
       ::= {acAnalogMisc 2}



     acAnalogMiscGroundKeyDetection OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Enables/disables the analog ground key detection.
0 = Disable
1= Enable.
Access: Offline.
AC INI-Param: GroundKeyDetection"
       ::= {acAnalogMisc 3}



     acAuxiliaryFiles OBJECT IDENTIFIER ::= {acAnalogConfig 2}


     acAuxiliaryFilesFxsCoefficients OBJECT-TYPE
       SYNTAX SnmpAdminString (SIZE (0..47))
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Defines the FXS loop coefficient filename.

Max. 47 characters.
AC INI-Param: FXSCOEFFILENAME"
       ::= {acAuxiliaryFiles 1}



     acAuxiliaryFilesFxoCoefficients OBJECT-TYPE
       SYNTAX SnmpAdminString (SIZE (0..47))
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Defines the FXO loop coefficient filename.

Max. 47 characters.
AC INI-Param: FXOCOEFFILENAME"
       ::= {acAuxiliaryFiles 2}



     acAnalogFxoConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 2}


     acAnalogFxo OBJECT IDENTIFIER ::= {acAnalogFxoConfig 1}


     acAnalogFxoFarEndDisconnectType OBJECT-TYPE
       SYNTAX Unsigned32 (0..128)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "This parameter sets the source for the acEV_FAR_END_DISCONNECTED
event (or for the relevant control protocol event). It
is a bit field parameter, hence (for example) if both CPT and
current disconnect are required, the parameter should be set
to 5.
FarDisconnect contributor:
1 = CPT
2 = PolarityReversal
4 = CurrentDisconnect
8 = Silence.
Access: Offline.
AC INI-Param: FARENDDISCONNECTTYPE"
       ::= {acAnalogFxo 1}



     acAnalogFxoCountryCoefficients OBJECT-TYPE
       SYNTAX INTEGER {
                  europe(66)
,
                  unitedStates(70)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Allows the user to modify the line characteristic (AC and DC)
according to country.
Access: Offline.
AC INI-Param: CountryCoefficients"
       ::= {acAnalogFxo 2}



     acAnalogFxoDCRemover OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Determines whether to enable the analog DC remover in the DAA.

One of the following values:

0 = DC remover is disabled
1 = DC remover is enabled.
Access: Offline.
AC INI-Param: EnableAnalogDCRemover"
       ::= {acAnalogFxo 3}



     acAnalogFxoDefaultLinePolarityState OBJECT-TYPE
       SYNTAX INTEGER {
                  positive-polarity(0)
,
                  negative-polarity(1)
,
                  polarity-auto-detect(2)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Sets the TTX pulses voltage level.
0 = 0Vrms sinusoidal bursts
1 = 0.5Vrms sinusoidal bursts
2 = 1Vrms  sinusoidal bursts.
Access: Offline.
AC INI-Param: SetDefaultLinePolarityState"
       ::= {acAnalogFxo 4}



     acAnalogFxoTxGainControl OBJECT-TYPE
       SYNTAX Integer32 (-15..12)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Sets gain\attenuation of the FXO Tx path between -15db and 12db.
default no gain.
Access: Offline.
AC INI-Param: FXOTxGainControl"
       ::= {acAnalogFxo 5}



     acAnalogFxoRxGainControl OBJECT-TYPE
       SYNTAX Integer32 (-15..12)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Sets gain\attenuation of the FXO Rx path between -15db and 12db.
default no gain.
Access: Offline.
AC INI-Param: FXORxGainControl"
       ::= {acAnalogFxo 6}



     -- ****************************************
     -- acAnalogFxoFarEndDisconnectTone table declaration
     -- ****************************************
     acAnalogFxoFarEndDisconnectToneTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcAnalogFxoFarEndDisconnectToneEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       ::= {acAnalogFxo 21}



     -- ****************************************
     -- acAnalogFxoFarEndDisconnectTone table entry
     -- ****************************************
     acAnalogFxoFarEndDisconnectToneEntry OBJECT-TYPE
       SYNTAX AcAnalogFxoFarEndDisconnectToneEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acAnalogFxoFarEndDisconnectToneIndex}
       ::= {acAnalogFxoFarEndDisconnectToneTable 1}



     -- ****************************************
     -- acAnalogFxoFarEndDisconnectTone TABLE
     -- ****************************************
     AcAnalogFxoFarEndDisconnectToneEntry ::= SEQUENCE {
       acAnalogFxoFarEndDisconnectToneRowStatus        Unsigned32,
       acAnalogFxoFarEndDisconnectToneAction           Unsigned32,
       acAnalogFxoFarEndDisconnectToneActionResult     Unsigned32,
       acAnalogFxoFarEndDisconnectToneIndex            Unsigned32,
       acAnalogFxoFarEndDisconnectToneType             INTEGER
     }



     acAnalogFxoFarEndDisconnectToneRowStatus OBJECT-TYPE
       SYNTAX Unsigned32 (1..1)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Far End Disconnect table row-status.
AC INI-Param: N/A"
       ::= {acAnalogFxoFarEndDisconnectToneEntry 1}



     acAnalogFxoFarEndDisconnectToneAction OBJECT-TYPE
       SYNTAX Unsigned32 (0..0)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Far End Disconnect table action.
AC INI-Param: N/A"
       ::= {acAnalogFxoFarEndDisconnectToneEntry 2}



     acAnalogFxoFarEndDisconnectToneActionResult OBJECT-TYPE
       SYNTAX Unsigned32 (0..0)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Far End Disconnect table result.
AC INI-Param: N/A"
       ::= {acAnalogFxoFarEndDisconnectToneEntry 3}



     acAnalogFxoFarEndDisconnectToneIndex OBJECT-TYPE
       SYNTAX Unsigned32 (0..4)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Index for table use.
AC INI-Param: N/A"
       ::= {acAnalogFxoFarEndDisconnectToneEntry 4}



     acAnalogFxoFarEndDisconnectToneType OBJECT-TYPE
       SYNTAX INTEGER {
                  acNullTone(0)
,
                  acDialTone(1)
,
                  acRingingTone(2)
,
                  acBusyTone(3)
,
                  acCongestionTone(4)
,
                  acSpecialInfoTone(5)
,
                  acWarningTone(6)
,
                  acReorderTone(7)
,
                  acConfirmationTone(8)
,
                  acWaitingTone(9)
,
                  acCallProgressCo1Tone(10)
,
                  acCallProgressCo2Tone(11)
,
                  acOldMilliwattTone(12)
,
                  acNewMilliwattTone(13)
,
                  acMessageWaitingIndicator(14)
,
                  acStutterDialTone(15)
,
                  acStutterOffHookWarningTone(16)
,
                  acWaitingTone1(17)
,
                  acComfortTone(18)
,
                  acNAKTone(19)
,
                  acVacantNumberTone(20)
,
                  acSpecialConditionTone(21)
,
                  acDialTone2(22)
,
                  acOnHoldTone(23)
,
                  acCallTransferDialTone(24)
,
                  acCallForwardTone(25)
,
                  acCreditCardServiceTone(26)
,
                  acSpecialRecallDialTone(27)
,
                  acAlertingTone(28)
,
                  acNetworkCongestionTone(29)
,
                  acWaitingTone2(30)
,
                  acWaitingTone3(31)
,
                  acWaitingTone4(32)
,
                  acConfEnterTone(33)
,
                  acConfExitTone(34)
,
                  acConfLockTone(35)
,
                  acConfUnlockTone(36)
,
                  acConfTimeLimitTone(37)
,
                  acPayphoneRecognitionTone(38)
,
                  acCallerWaitingTone(39)
,
                  acCNGFaxTone(40)
,
                  acPrecConfNotifyType(41)
,
                  acPresConfNotifyType(42)
,
                  acPrecPreemptType(43)
,
                  acPrecRTType(44)
,
                  acR15reqOfANItone(45)
,
                  acCo1Tone(200)
,
                  acCo2Tone(201)
,
                  acPlayRecordBeepTone(202)
,
                  acTrunkTestingTestProgressTone(203)
,
                  acTrunkTestingTestTone(204)
,
                  acTrunkTestingGuardTone(205)
,
                  acFSKTrunkTestingTone(206)
,
                  acGeneralTrunkTestingTone1(207)
,
                  acGeneralTrunkTestingTone2(208)
,
                  acGeneralTrunkTestingTone3(209)
,
                  acSpecialInfoToneFirst(210)
,
                  acSpecialInfoToneSecond(211)
,
                  acSpecialInfoToneThird(212)
,
                  acTTYTone(213)
,
                  acTT904ContinuityTone(214)
,
                  acTTMilliwattLossMeasureTone(215)
,
                  acCarrierDialTone(216)
,
                  acCarrierAnswerTone(217)
,
                  acCarrierChargingTone(218)
,
                  acLongDistanceIndicatorTone(219)
,
                  acSTUModemFirstTone(298)
,
                  acSTUModemSecondTone(299)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Defines which CPT types are detected as far-end disconnect.
The CPT type is based on  the  acTCallProgressToneType enum.
This is valid when FarEndDisconnectType allows CPT detection.

Range = An array of up to 4 tone types.
Access: Offline.
AC INI-Param: DISCONNECTTONETYPE"
       ::= {acAnalogFxoFarEndDisconnectToneEntry 5}



     acAnalogFxsConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 3}


     acAnalogFxs OBJECT IDENTIFIER ::= {acAnalogFxsConfig 1}


     acAnalogFxsPolarityReversalType OBJECT-TYPE
       SYNTAX INTEGER {
                  soft(0)
,
                  hard(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Sets the type of the polarity reversal signal used for the network
far-end answer and disconnect indications. Smooth reversal
prevents negative effects as non-required ringing.
0 = Soft reverse polarity
1 = Hard reverse polarity.
Access: Offline.
AC INI-Param: POLARITYREVERSALTYPE"
       ::= {acAnalogFxs 1}



     acAnalogFxsMeteringType OBJECT-TYPE
       SYNTAX INTEGER {
                  mt12kHz(0)
,
                  mt16kHz(1)
,
                  mtPolarityReversal(2)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Sets the metering method for charging pulses.
0 = 12 kHz sinusoidal bursts
1 = 16 kHz sinusoidal bursts
2 = Polarity Reversal pulses.
Access: Offline.
AC INI-Param: METERINGTYPE"
       ::= {acAnalogFxs 2}



     acAnalogFxsLifeLineType OBJECT-TYPE
       SYNTAX INTEGER {
                  acLifeLineType-Hardware-Only(0)
,
                  acLifeLineTypeHardware-And-Link-Detection(1)
,
                  acLifeLineType-Hardware-And-Link-And-Network-Detection(2)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Defines the Lifeline phone type. The Lifeline phone is available
(for FXS only) on port 4 in MP-104 and MP-108, on port
2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each
analog module in the Mediant 1000. 
0 = activate Lifeline phone on power down 
1 = activate Lifeline phone on power down or on detection of
LAN disconnect 
2 = activate Lifeline phone on power down, or on detection
of LAN disconnect, or on loss of ping.
Access: Offline.
AC INI-Param: LIFELINETYPE"
       ::= {acAnalogFxs 3}



     acAnalogFxsMinFlashHookTime OBJECT-TYPE
       SYNTAX Unsigned32 (25..300)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Sets the minimal time (in msec) for detection of a flash-hook
event (for FXS only). The valid range is 25 to 300. The default
value is 300 msec.

Detection is guaranteed for flash hook periods of at least
60 msec (when setting the minimal time to 25). Flash-hook signals
that last a shorter period of time are ignored.

Note: It is recommended to reduce the detection time by 50
msec from the desired value (e.g. if you set the value as 200
msec, then enter 150 msec, i.e. 200 minus 50).
.
Access: Offline.
AC INI-Param: MINFLASHHOOKTIME"
       ::= {acAnalogFxs 4}



     acAnalogFxsCallerIDTimingMode OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Defines the Analog CallerID Timing Mode.

0 = CallerID transferred between first and second rings 
1 = CallerID transferred on valid Off ring.
Access: Offline.
AC INI-Param: ANALOGCALLERIDTIMINGMODE"
       ::= {acAnalogFxs 5}



     acAnalogFxsBellcoreCallerIDTypeOneSubStandard OBJECT-TYPE
       SYNTAX INTEGER {
                  bellcore-Between-Rings(0)
,
                  bellcore-Not-Ring-Related(1)
,
                  bellcore-Before-Ring-RP-AS(2)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Selects the sub-standard of the Bellcore Caller ID type. 

0 = Between_Rings 
1 = Not_Ring_Related
2 = Before_Ring_RP_AS.
Access: Offline.
AC INI-Param: BellcoreCallerIDTypeOneSubStandard"
       ::= {acAnalogFxs 6}



     acAnalogFxsETSICallerIDTypeOneSubStandard OBJECT-TYPE
       SYNTAX INTEGER {
                  eTSI-Between-Rings(0)
,
                  eTSI-Before-Ring-DT-AS(1)
,
                  eTSI-Before-Ring-RP-AS(2)
,
                  eTSI-Before-Ring-LR-DT-AS(3)
,
                  eTSI-Not-Ring-Related-DT-AS(4)
,
                  eTSI-Not-Ring-Related-RP-AS(5)
,
                  eTSI-Not-Ring-Related-LR-DT-AS(6)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Selects the number denoting the ETSI CallerID Type 1 sub-standard.
Either:
0 = ETSI_Between_Rings 
1 = ETSI_Before_Ring_DT_AS 
2 = ETSI_Before_Ring_RP_AS 
3 = ETSI_Before_Ring_LR_DT_AS  
4 = ETSI_Not_Ring_Related_DT_AS 
5 = ETSI_Not_Ring_Related_RP_AS 
6 = ETSI_Not_Ring_Related_LR_DT_AS.
Access: Offline.
AC INI-Param: ETSICallerIDTypeOneSubStandard"
       ::= {acAnalogFxs 7}



     acAnalogFxsETSIVMWITypeOneStandard OBJECT-TYPE
       SYNTAX INTEGER {
                  eTSI-VMWI-Between-Rings(0)
,
                  eTSI-VMWI-Before-Ring-DT-AS(1)
,
                  eTSI-VMWI-Before-Ring-RP-AS(2)
,
                  eTSI-VMWI-Before-Ring-LR-DT-AS(3)
,
                  eTSI-VMWI-Not-Ring-Related-DT-AS(4)
,
                  eTSI-VMWI-Not-Ring-Related-RP-AS(5)
,
                  eTSI-VMWI-Not-Ring-Related-LR-DT-AS(6)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Selects the number denoting the ETSI VMWI Type 1 Standard.
Choose:
0 = ETSI_VMWI_Between_Rings 
1 = ETSI_VMWI_Before_Ring_DT_AS 
2 = ETSI_VMWI_Before_Ring_RP_AS 
3 = ETSI_VMWI_Before_Ring_LR_DT_AS  
4 = ETSI_VMWI_Not_Ring_Related_DT_AS 
5 = ETSI_VMWI_Not_Ring_Related_RP_AS 
6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS.
Access: Offline.
AC INI-Param: ETSIVMWITypeOneStandard"
       ::= {acAnalogFxs 8}



     acAnalogFxsBellcoreVMWITypeOneStandard OBJECT-TYPE
       SYNTAX INTEGER {
                  bellcore-VMWI-Between-Rings(0)
,
                  bellcore-VMWI-Not-Ring-Related(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Use this parameter to select the Bellcore VMWI standard.

0 - Between_Rings 
1 - Not_Ring_Related.
Access: Offline.
AC INI-Param: BellcoreVMWITypeOneStandard"
       ::= {acAnalogFxs 9}



     acAnalogFxsDisableAutoCalibration OBJECT-TYPE
       SYNTAX Unsigned32
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Determines whether to enable the analog Autocalibration in the
DAA.

One of the following values:

0 = Auto calibration is enabled
1 = Auto calibration is disabled.
Access: Offline.
AC INI-Param: DisableAnalogAutoCalibration"
       ::= {acAnalogFxs 10}



     acAnalogFxsExternalLifeLinePorts OBJECT-TYPE
       SYNTAX Unsigned32 (0..24)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Set the amount of FXS ports which will be connected to an external
life line and will be disabled (max value is half of
the FXS ports).
Access: Offline.
AC INI-Param: ExternalLifeLinePorts"
       ::= {acAnalogFxs 11}



     acAnalogFxsCountryCoefficients OBJECT-TYPE
       SYNTAX INTEGER {
                  europe(66)
,
                  unitedStates(70)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Allows the user to modify the line characteristic (AC and DC)
according to country.
Access: Offline.
AC INI-Param: FXSCountryCoefficients"
       ::= {acAnalogFxs 12}



     acAnalogFxsTTXVoltageLevel OBJECT-TYPE
       SYNTAX INTEGER {
                  notAvailable(-1)
,
                  ttxVoltageLevel0V(0)
,
                  ttxVoltageLevel05(1)
,
                  ttxVoltageLevel1V(2)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Sets the TTX pulses voltage level.
0 = 0Vrms sinusoidal bursts
1 = 0.5Vrms sinusoidal bursts
2 = 1Vrms  sinusoidal bursts
-1 = notAvailable.
Access: Offline.
AC INI-Param: AnalogTTXVoltageLevel"
       ::= {acAnalogFxs 13}



     acAnalogEMConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 4}


     acAnalogEM OBJECT IDENTIFIER ::= {acAnalogEMConfig 1}


     acAnalogEMVoiceType OBJECT-TYPE
       SYNTAX INTEGER {
                  twoWire(0)
,
                  fourWire(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "E&M Voice Configuration Type 2 or 4 wire.
Access: Offline.
AC INI-Param: EnMVoiceType"
       ::= {acAnalogEM 1}



     acAnalogEMInterfaceType OBJECT-TYPE
       SYNTAX INTEGER {
                  signaling(0)
,
                  trunking(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "E&M Signaling Type - Trunking or Signaling.
Access: Offline.
AC INI-Param: EnMSystemType"
       ::= {acAnalogEM 2}



     acAnalogEMSignalingType OBJECT-TYPE
       SYNTAX Unsigned32 (1..5)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Set E&M standatd signaling types are described in TIA/EIA-464C.
Access: Offline.
AC INI-Param: EnMSignalingType"
       ::= {acAnalogEM 3}



     acAnalogEMPortRXGain OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Rx Gain.
Access: Offline.
AC INI-Param: EnMPortRXGain"
       ::= {acAnalogEM 4}



     acAnalogEMPortTXGain OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Tx Gain.
Access: Offline.
AC INI-Param: EnMPortTXGain"
       ::= {acAnalogEM 5}



     acAnalogEMCountryCoefficients OBJECT-TYPE
       SYNTAX INTEGER {
                  unitedStates(0)
,
                  europe(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "E&M Country Coefficients.
Access: Offline.
AC INI-Param: EnMCountryCoefficients"
       ::= {acAnalogEM 6}



     acAnalogEMHookDebounceTiming OBJECT-TYPE
       SYNTAX Unsigned32 (30..150)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Sets the on E&M hook detection debounce timing.
Access: Offline.
AC INI-Param: EnMhookDebounceTiming"
       ::= {acAnalogEM 7}



     acAnalogEMOffHookGlareEnable OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Protect the EnM port from Rx and Tx hook collision.
Access: Offline.
AC INI-Param: EnMOffHookGlareEnable"
       ::= {acAnalogEM 8}



     acAnalogStatus OBJECT IDENTIFIER ::= {acAnalog 2}


     acAnalogStatusMisc OBJECT IDENTIFIER ::= {acAnalogStatus 1}


     acAnalogStatusMiscFxsOrFxo OBJECT-TYPE
       SYNTAX INTEGER {
                  fXO(0)
,
                  fXS(1)
,
                  eANDm(2)
,
                  fXOandFXS(3)
,
                  fXOandFXSandEM(5)
,
                  fXOandEM(6)
,
                  fXSandEM(7)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Board is Fxs,Fxo, FXS_FXO or  E&M.
AC INI-Param: N/A"
       ::= {acAnalogStatusMisc 1}



     acAnalogStatusMiscBoardTemperature OBJECT-TYPE
       SYNTAX Unsigned32 (0..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Temperature of the board in degrees Celsius, should not go higher
then 60!.
AC INI-Param: N/A"
       ::= {acAnalogStatusMisc 2}



     acAnalogStatusMiscAnalogChannelsCount OBJECT-TYPE
       SYNTAX Unsigned32 (0..5000)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Number of the Analog channels in the board.
AC INI-Param: N/A"
       ::= {acAnalogStatusMisc 3}



     acAnalogFxsFxo OBJECT IDENTIFIER ::= {acAnalogStatus 20}


     -- ****************************************
     -- acAnalogFxsFxo table declaration
     -- ****************************************
     acAnalogFxsFxoTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcAnalogFxsFxoEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       ::= {acAnalogFxsFxo 1}



     -- ****************************************
     -- acAnalogFxsFxo table entry
     -- ****************************************
     acAnalogFxsFxoEntry OBJECT-TYPE
       SYNTAX AcAnalogFxsFxoEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acAnalogFxsFxoIndex}
       ::= {acAnalogFxsFxoTable 1}



     -- ****************************************
     -- acAnalogFxsFxo TABLE
     -- ****************************************
     AcAnalogFxsFxoEntry ::= SEQUENCE {
       acAnalogFxsFxoIndex                             Unsigned32,
       acAnalogFxsFxoType                              INTEGER,
       acAnalogFxsFxoChipRevNum                        Unsigned32,
       acAnalogFxsFxoHookState                         INTEGER
     }



     acAnalogFxsFxoIndex OBJECT-TYPE
       SYNTAX Unsigned32 (0..24)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Index for table use.
AC INI-Param: N/A"
       ::= {acAnalogFxsFxoEntry 1}



     acAnalogFxsFxoType OBJECT-TYPE
       SYNTAX INTEGER {
                  fXO(0)
,
                  fXS(1)
,
                  eM(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Line is Fxs, Fxo or E&M.
AC INI-Param: N/A"
       ::= {acAnalogFxsFxoEntry 2}



     acAnalogFxsFxoChipRevNum OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Fxs/Fxo's  Chip revision number.
AC INI-Param: N/A"
       ::= {acAnalogFxsFxoEntry 3}



     acAnalogFxsFxoHookState OBJECT-TYPE
       SYNTAX INTEGER {
                  onHookState(1)
,
                  offHookState(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The hook state of the analog line.
AC INI-Param: N/A"
       ::= {acAnalogFxsFxoEntry 4}



     acAnalogAction OBJECT IDENTIFIER ::= {acAnalog 3}


     acAnalogFxoAction OBJECT IDENTIFIER ::= {acAnalogAction 1}


     -- ****************************************
     -- acAnalogFxoLineTest table declaration
     -- ****************************************
     acAnalogFxoLineTestTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcAnalogFxoLineTestEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       ::= {acAnalogFxoAction 1}



     -- ****************************************
     -- acAnalogFxoLineTest table entry
     -- ****************************************
     acAnalogFxoLineTestEntry OBJECT-TYPE
       SYNTAX AcAnalogFxoLineTestEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acAnalogFxoLineTestIndex}
       ::= {acAnalogFxoLineTestTable 1}



     -- ****************************************
     -- acAnalogFxoLineTest TABLE
     -- ****************************************
     AcAnalogFxoLineTestEntry ::= SEQUENCE {
       acAnalogFxoLineTestIndex                        Unsigned32,
       acAnalogFxoLineTestActivate                     INTEGER,
       acAnalogFxoLineTestHookState                    INTEGER,
       acAnalogFxoLineTestPolarityStatus               INTEGER,
       acAnalogFxoLineTestLineConnectionStatus         INTEGER,
       acAnalogFxoLineTestLineCurrent                  Integer32,
       acAnalogFxoLineTestLineVoltage                  Integer32,
       acAnalogFxoLineTestRingState                    INTEGER,
       acAnalogFxoLineTestLinePolarity                 INTEGER,
       acAnalogFxoLineTestMwiState                     INTEGER,
       acAnalogFxoLineTestLastCurrentDisconnectDuration 
                                                       Unsigned32
     }



     acAnalogFxoLineTestIndex OBJECT-TYPE
       SYNTAX Unsigned32 (0..24)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Index for table use.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 1}



     acAnalogFxoLineTestActivate OBJECT-TYPE
       SYNTAX INTEGER {
                  noTestActivated(0)
,
                   runLineTest(1)
,
                   lineTestDone(2)
,
                   testFailed(3)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Activate line testing in an FXO analog line according to a given
line-index.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 2}



     acAnalogFxoLineTestHookState OBJECT-TYPE
       SYNTAX INTEGER {
                  onHookState(1)
,
                  offHookState(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The hook state of the analog line.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 3}



     acAnalogFxoLineTestPolarityStatus OBJECT-TYPE
       SYNTAX INTEGER {
                  normalPolarity(1)
,
                   reversePolarity(2)
,
                  notAvailable(3)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The line's polarity state.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 4}



     acAnalogFxoLineTestLineConnectionStatus OBJECT-TYPE
       SYNTAX INTEGER {
                  lineDisconnected(1)
,
                   lineConnected(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The connection's status of the line.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 5}



     acAnalogFxoLineTestLineCurrent OBJECT-TYPE
       SYNTAX Integer32 (-1..24)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The line's current [ma].
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 6}



     acAnalogFxoLineTestLineVoltage OBJECT-TYPE
       SYNTAX Integer32 (-128..128)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The line's voltage [V].
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 7}



     acAnalogFxoLineTestRingState OBJECT-TYPE
       SYNTAX INTEGER {
                  off(1)
,
                  on(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The Ring's State.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 8}



     acAnalogFxoLineTestLinePolarity OBJECT-TYPE
       SYNTAX INTEGER {
                  positive(1)
,
                  negative(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The line's polarity state.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 9}



     acAnalogFxoLineTestMwiState OBJECT-TYPE
       SYNTAX INTEGER {
                  off(1)
,
                  on(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Mwi's state.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 10}



     acAnalogFxoLineTestLastCurrentDisconnectDuration OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Last current disconnect duration in msec.
AC INI-Param: N/A"
       ::= {acAnalogFxoLineTestEntry 11}



     acAnalogFxsAction OBJECT IDENTIFIER ::= {acAnalogAction 2}


     -- ****************************************
     -- acAnalogFxsLineTest table declaration
     -- ****************************************
     acAnalogFxsLineTestTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcAnalogFxsLineTestEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       ::= {acAnalogFxsAction 1}



     -- ****************************************
     -- acAnalogFxsLineTest table entry
     -- ****************************************
     acAnalogFxsLineTestEntry OBJECT-TYPE
       SYNTAX AcAnalogFxsLineTestEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acAnalogFxsLineTestIndex}
       ::= {acAnalogFxsLineTestTable 1}



     -- ****************************************
     -- acAnalogFxsLineTest TABLE
     -- ****************************************
     AcAnalogFxsLineTestEntry ::= SEQUENCE {
       acAnalogFxsLineTestIndex                        Unsigned32,
       acAnalogFxsLineTestActivate                     INTEGER,
       acAnalogFxsLineTestHookState                    INTEGER,
       acAnalogFxsLineTestRingState                    INTEGER,
       acAnalogFxsLineTestPolarityStatus               INTEGER,
       acAnalogFxsLineTestMessageWaitingIndication     INTEGER,
       acAnalogFxsLineTestLineCurrentReading           Unsigned32,
       acAnalogFxsLineTestLineVoltageReading           Integer32,
       acAnalogFxsLineTestAnalogVoltageReading         Unsigned32,
       acAnalogFxsLineTestRingVoltageReading           Integer32,
       acAnalogFxsLineTestLongLineCurrentReading       Unsigned32
     }



     acAnalogFxsLineTestIndex OBJECT-TYPE
       SYNTAX Unsigned32 (0..24)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Index for table use.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 1}



     acAnalogFxsLineTestActivate OBJECT-TYPE
       SYNTAX INTEGER {
                  noTestActivated(0)
,
                   runLineTest(1)
,
                   lineTestDone(2)
,
                   testFailed(3)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Activate line testing in a FXS analog line according to a given
line-index.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 2}



     acAnalogFxsLineTestHookState OBJECT-TYPE
       SYNTAX INTEGER {
                  onHookState(1)
,
                  offHookState(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The hook state of the analog line.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 3}



     acAnalogFxsLineTestRingState OBJECT-TYPE
       SYNTAX INTEGER {
                  offRingState(1)
,
                   onRingState(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Line's ring state.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 4}



     acAnalogFxsLineTestPolarityStatus OBJECT-TYPE
       SYNTAX INTEGER {
                  normalPolarity(1)
,
                   reversePolarity(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Line's reversal-polarity.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 5}



     acAnalogFxsLineTestMessageWaitingIndication OBJECT-TYPE
       SYNTAX INTEGER {
                  noWaitingMessage(1)
,
                  waitingMessage(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Line's messgae waiting indication state.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 6}



     acAnalogFxsLineTestLineCurrentReading OBJECT-TYPE
       SYNTAX Unsigned32 (0..3000)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "The Line current reading in 10ua units.
This test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 7}



     acAnalogFxsLineTestLineVoltageReading OBJECT-TYPE
       SYNTAX Integer32 (-6000..6000)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "The Line voltage reading in 10mV units.
In case of MP124 the Line voltage reading in 1V units.
This test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 8}



     acAnalogFxsLineTestAnalogVoltageReading OBJECT-TYPE
       SYNTAX Unsigned32 (300..340)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "The current analog voltage reading in 10mV units.
his test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 9}



     acAnalogFxsLineTestRingVoltageReading OBJECT-TYPE
       SYNTAX Integer32 (-13000..13000)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "The current ring voltage reading in 10mV units.
This test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 10}



     acAnalogFxsLineTestLongLineCurrentReading OBJECT-TYPE
       SYNTAX Unsigned32 (0..4000)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "The current long line reading in 10ua units.
This test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
       ::= {acAnalogFxsLineTestEntry 11}



     acAnalogCommonAction OBJECT IDENTIFIER ::= {acAnalogAction 3}


     -- ****************************************
     -- acAnalogCommonChannel table declaration
     -- ****************************************
     acAnalogCommonChannelTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcAnalogCommonChannelEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Table for common channels operations."
       ::= {acAnalogCommonAction 1}



     -- ****************************************
     -- acAnalogCommonChannel table entry
     -- ****************************************
     acAnalogCommonChannelEntry OBJECT-TYPE
       SYNTAX AcAnalogCommonChannelEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acAnalogCommonChannelIndex}
       ::= {acAnalogCommonChannelTable 1}



     -- ****************************************
     -- acAnalogCommonChannel TABLE
     -- ****************************************
     AcAnalogCommonChannelEntry ::= SEQUENCE {
       acAnalogCommonChannelIndex                      Unsigned32,
       acAnalogCommonChannelAction                     INTEGER
     }



     acAnalogCommonChannelIndex OBJECT-TYPE
       SYNTAX Unsigned32 (0..5000)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Index for table use, the current channel.
AC INI-Param: N/A"
       ::= {acAnalogCommonChannelEntry 1}



     acAnalogCommonChannelAction OBJECT-TYPE
       SYNTAX INTEGER {
                  noAction(0)
,
                  reset(1)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "An action to make on the current channel, The Reset action is
for Analog channels only.
AC INI-Param: N/A"
       ::= {acAnalogCommonChannelEntry 2}



     acAnalogLegs OBJECT IDENTIFIER ::= {acAnalogStatus 21}


     -- ****************************************
     -- acAnalogLegs table declaration
     -- ****************************************
     acAnalogLegsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcAnalogLegsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       ::= {acAnalogLegs 1}



     -- ****************************************
     -- acAnalogLegs table entry
     -- ****************************************
     acAnalogLegsEntry OBJECT-TYPE
       SYNTAX AcAnalogLegsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acAnalogLegsLegIndex}
       ::= {acAnalogLegsTable 1}



     -- ****************************************
     -- acAnalogLegs TABLE
     -- ****************************************
     AcAnalogLegsEntry ::= SEQUENCE {
       acAnalogLegsLegIndex                            Unsigned32,
       acAnalogLegsCallIndex                           Unsigned32,
       acAnalogLegsAnalogType                          INTEGER,
       acAnalogLegsEchoCanceller                       INTEGER,
       acAnalogLegsHighPassFilter                      INTEGER,
       acAnalogLegsDTMFDetection                       INTEGER,
       acAnalogLegsVoiceVolume                         Unsigned32,
       acAnalogLegsInputGain                           Unsigned32,
       acAnalogLegsLegName                             SnmpAdminString
     }



     acAnalogLegsLegIndex OBJECT-TYPE
       SYNTAX Unsigned32 (0..5000)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Decribes The Digital EndPoint In A Call.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 1}



     acAnalogLegsCallIndex OBJECT-TYPE
       SYNTAX Unsigned32 (0..5000)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Decribes The Call which The Rtp EndPoint Participant In It.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 2}



     acAnalogLegsAnalogType OBJECT-TYPE
       SYNTAX INTEGER {
                  fxs(1)
,
                  fxo(2)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Describs whether the board is FXS or FXO.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 3}



     acAnalogLegsEchoCanceller OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Enables or Disables the Echo Canceller.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 4}



     acAnalogLegsHighPassFilter OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Enables or Disables theHigh Pass Filter.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 5}



     acAnalogLegsDTMFDetection OBJECT-TYPE
       SYNTAX INTEGER {
                  disable(0)
,
                  enable(1)

                  }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Enables or Disables the DTMF Detection.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 6}



     acAnalogLegsVoiceVolume OBJECT-TYPE
       SYNTAX Unsigned32 (0..20000)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Describs the volume of the voice in dB.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 7}



     acAnalogLegsInputGain OBJECT-TYPE
       SYNTAX Unsigned32 (0..20000)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Describes the Input Gain on the leg in dB.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 8}



     acAnalogLegsLegName OBJECT-TYPE
       SYNTAX SnmpAdminString (SIZE (0..64))
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Describes the Leg Name as in the Control Protocol.
AC INI-Param: N/A"
       ::= {acAnalogLegsEntry 9}





END